Arguments can be passed when starting Configuration manager (CMG):

ETCP task will not be started

Example1 working on Windows NT : ISaGRAF -RSI=COM1:19200:N:1:OFF -NoETCP.

Example 2 working on Windows NT: create a ‘isagraf.ini’ file that contains lines below, and start CMG with no parameter on command line.

[APP]

NoETCP=1

ResNbr=20

s=1

RSI=COM1:19200:N:1:OFF

____________________________________________________________________